4. Installation

Be sure to take the following cautions and instructions into account when
installing the pump.

4.1 Movement and Fixation

4.1.1 Location

These pumps are designed for indoor installation. To install the pump, select a
place with little exposure to dust and humidity and not subject to dew
condensation. Also allow for sufficient space to ensure easy pump installation
and disassembly for maintenance.
CAUTION Install pump in a location at an ambient not exceeding 30°C.
CAUTION A gap of at least 50mm should be left open for ventilation

4.1.2 Caster and adjustment foot

Casters and adjusters of four each are attached under the pump base. When
moving the pump, lift up all of the four adjusters. To lift them up, use the
wrench and turn them to the left.
PM10U
Particular caution is required when the pump is operated in
an enclosed room.
between the pump cover and the adjacent equipment.
Fig. 4.1 Caster
P.33
EBARA
CORPORATION