EBARA EV-S20 Instruction Manual page 70

Multi-stage dry vacuum pump ce / semi / nrtl model 200-220v(50/60hz)
Table of Contents

Advertisement

Pin No.
Signal name
1
RESET (+)
2
SAVING ENERGY CONTROL (+)
3
RESERVED (+)
4
RESERVED (+)
5
RESERVED (+)
6
EMS STATUS (+) *1
7
PUMP N2 WARNING STATUS (+) *2
8
RESERVED (+)
9
SAVING ENERGY STATUS (+)
10
RESERVED (+)
11
RESERVED (+)
12
RESERVED (+)
13
14
RESET (−)
15
SAVING ENERGY CONTROL (−)
16
RESERVED (−)
17
RESERVED (−)
18
RESERVED (−)
19
EMS STATUS (−) *1
20
PUMP N2 WARNING STATUS (−)*2
21
RESERVED (−)
22
SAVING ENERGY STATUS (−)
23
RESERVED (−)
24
RESERVED (−)
25
RESERVED (−)
*1 : Optional
*2 : Only "P" and "N" model.
*3 : It can change to "Abnormality:OPEN, Alternate" by DIP SW. setting.
PM10U
13
25
25 Pin D Sub-Miniature Female Receptacle
(As seen from connecting side)
Table 4.8 Control Connector Pin Assignment (CN-Y)
Screw lock size: M2.6
1
14
Contact pin surface: Au
Fig. 4.7
I/O
Signal type
IN
RESET:CLOSE
SAVING ENERGY MODE:CLOSE,
IN
Alternate
IN
IN
IN
OUT
EMS:OPEN, Alternate
OUT
Abnormality:CLOSE, Alternate *3
OUT
SAVING ENERGY MODE:CLOSE,
OUT
Alternate
OUT
OUT
OUT
P.51
EBARA
CORPORATION

Hide quick links: