Table C-8 Warning/Status Messages For Raus; Section C.8 Messages For Raus - ADC InterReach Fusion Installation, Operation And Reference Manual

Table of Contents

Advertisement

C.8
D-620610-0-20 Rev D
Messages for RAUs
In Table C-8, the message number is in the following form:
[Rnn]/X where nn equals the message number, and X equals the default of either Sta-
tus (S) or Warning (W).
Warning/Status Messages for RAUs
Table C-8
Message
Number
Default
Description
[R01]/W
Temperature High.
[R02]/W
No communications from Hub.
[R03]/W
DL RF path loss is too high.
[R04]/W
DL RF path exceeds maximum
gain.
[R05]/S
DL RF path problem (Band 1).
[R06]/S
DL RF path problem (Band 2).
[R07]/S
DL RF path problem (Band 3).
[R08]/S
System test required.
[R09]/W
Antenna Disconnected.
[R10]/S
UL RF path problem (Band 1).
[R11]/S
UL RF path problem (Band 2).
[R12]/S
UL RF path problem (Band 3).
[R13]/S
Problem detected in the RAU.
[R14]/S
Problem detected in the RAU.
[R15]/S
Problem detected in the RAU.
[R16]/S
Problem detected in the RAU.
Help Hot Line (U.S. only): 1-800-530-9960
Reason/Action
Check RAU location for excessive temperature; check for
air flow blockage and/or incorrect installation. Move the
RAU to a cooler environment.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem persists, replace
the RAU.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem persists, replace
the RAU.
Check the Hub for proper operation; switch the cable con-
nection to a different hub port. If the problem persists,
replace the RAU.
Unable to complete the DL system end-to-end test, replace
the RAU when possible.
Unable to complete the DL system end-to-end test, replace
the RAU when possible.
Unable to complete the DL system end-to-end test, replace
the RAU when possible.
Run system test.
Check RAU antenna connection; re-run system test.
Unable to complete the UL system end-to-end test, replace
the RAU when possible.
Unable to complete the UL system end-to-end test, replace
the RAU when possible.
Unable to complete the UL system end-to-end test, replace
the RAU when possible.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
C-19
CONFIDENTIAL