Fault Messages for Main Hubs
Table C-1
Message
Number
Description
{MF01}
Software error occurred and recovered.
{MF02}
Software error occurred and recovered.
{MF03}
Software error occurred and recovered.
{MF04}
Software reset occurred and recovered, or
firmware download.
{MF05}
Software error occurred and recovered.
{MF06}
Problem detected in the Hub. Internal
communication reset.
{MF07}
Hub power cycle.
{MF08}
Internal communications failure.
{MF09}
Hardware Reset.
{MF10}
Band not programmed.
{MF11}
Hardware failure (DL Pilot PLL).
{MF12}
Hardware failure (DL Pilot Too High).
{MF13}
Hardware failure (DL Pilot Too Low).
{MF14}
Hardware failure (54 VDC).
{MF15}
Hardware failure (RF VDC Power).
{MF16}
Self Lockout (All Bands).
{MF17}
Hardware failure (DL PLL Band 1).
{MF18}
Hardware failure (UL PLL Band 1).
{ML19}
Commanded Out-of-service (Band 1).
{MF20}
Hardware failure (UL1 LO2 Band 1).
{MF21}
Problem detected in the Hub.
{MF22}
Problem detected in the Hub.
{MF23}
Problem detected in the Hub
{MF24}
Problem detected in the Hub.
{MF25}
Hardware failure (DL PLL Band 2).
{MF26}
Hardware failure (UL PLL Band 2).
{ML27}
Commanded Out-of-service (Band 2).
{MF28}
Problem detected in the Hub.
{MF29}
Problem detected in the Hub.
{MF30}
Problem detected in the Hub.
{MF31}
Problem detected in the Hub.
{MF32}
Problem detected in the Hub.
InterReach Fusion Installation, Operation, and Reference Manual
LED without a fault message, it probably
STATUS
Reason/Action
If this happens repeatedly, replace the Hub.
If this happens repeatedly, replace the Hub.
If this happens repeatedly, replace the Hub.
If this happens repeatedly, replace the Hub.
If this happens repeatedly, replace the Hub.
Contact ADC Support for more information.
Hub power cycle.
No internal communications in preceding 15 min-
utes.
Commanded hardware power on reset
Use AdminBrowser to program the band.
Cycle power once. If fault persists, replace the Hub
Cycle power once. If fault persists, replace the Hub.
Cycle power once. If fault persists, replace the Hub.
54 VDC power supply is out of range, replace the
Hub
Loss of DC power to RF circuits, replace the Hub.
Hub has shutdown the system due to an internal fault.
System is offline.
Cycle power once. If fault persists, replace the Hub.
Cycle power once. If fault persists, replace the Hub
Band 1 commanded out-of-service by User.
Cycle power once. If the fault persists, replace the
Hub.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
Cycle power once. If fault persists, replace the Hub.
Cycle power once. If fault persists, replace the Hub.
Band 2 commanded out-of-service by User.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
Contact ADC Support for more information.
D-620610-0-20 Rev D