Note:
There are two switches controlling the report of alarm to the command line terminal.
Switch 1: Use the command infoswitch cli to set whether to report alarm
information to the command line terminal. Switch 2: Use the command (no) alarm
output to set whether to send the corresponding alarm to the command line
terminal by a certain condition. To sum up, switch 1 controls the output of all the
alarm information, while switch 2 controls the output of information according to the
alarm classes. Please refer to section 7.1.6 I. for the use of switch 1.
Each alarm has an output flag, which is used to identify whether
the alarm should be outputted to command line, and the output
setting command is also executed on the basis of this flag.
The basic command used for setting alarm output is:
(no) alarm output.
no is an optional item. no alarm output indicates the setting of
not outputting a certain type of alarms to command line. alarm
output indicates the setting of outputting a certain type of alarms to
command line.
I.
Setting by Alarm ID
Command: (no) alarm output alarmid id
Because alarm ID is unique for an alarm, this command will
enable your to set clearly whether to output a certain type of alarms.
Description of principal parameter:
Chapter 7 Maintaining System