Item
The alarm number from which the display starts, the value range is
1–1000. In the Command Line Interface (CLI), you can start the
startnum
display from 1, or from a designated startnum.
Maximum number of alarm records after the startnum that can be
number
displayed in one time. It is an optional parameter, ranging 1–1000.
IV.
Querying by Alarm Type
show alarm record alarmtype type_value [startnum number]
You can use this command to query the alarms by alarm type.
The meanings of the parameters in the command are listed in
Table 7-13.
Table 7-13 Parameters of command
Item
Alarm type. There are five types: communication alarm,
service_quality alarm, process_error alarm, equipment alarm and
type_value
environmental alarm. It is only necessary to input the English word
indicating the corresponding type directly.
The alarm number from which the display starts, the value range is
startnum
1–1000. In the Command Line Interface (CLI), you can start the
display from 1, or from a designated startnum.
Maximum number of alarm records after the startnum that can be
number
displayed in one time. It is an optional parameter, ranging 1–1000.
Chapter 7 Maintaining System
Description
Description
7-49