Huawei IAD108A User Manual page 236

Iad108 series access media gateway (amg)
Table of Contents

Advertisement

User Manual
U-SYS IAD108 Integrated Access Device
This method can be adopted when you want to query whether a
certain alarm is generated. The meanings of the parameters in the
command are listed in Table 7-11.
Table 7-11 Parameters of the command
Item
id
Alarm ID, ranging 52–1572886.
The alarm number from which the display starts, the value range is
startnum
1–1000. In the Command Line Interface (CLI), you can start the
display from 1, or from a designated startnum.
Maximum number of alarm records after the startnum that can be
number
displayed in one time. It is an optional parameter, ranging 1–1000.
III.
Querying by Alarm Level
Command: show alarm record alarmlevel level [startnum
number]
This method can be adopted for showing alarm record if you
only focus on alarms of a certain level. The meanings of the
parameters in the command are listed in Table 7-12.
Table 7-12 Parameters of command
Item
Alarm level. There are four levels. It is only necessary to input the
level
English word indicating the corresponding level directly.
Chapter 7 Maintaining System
Description
Description
7-48