Huawei IAD108A User Manual page 229

Iad108 series access media gateway (amg)
Table of Contents

Advertisement

User Manual
U-SYS IAD108 Integrated Access Device
Note:
When setting the information output control level for a log host, such log host
must be activated.
Only when the switch of related information type is set to on, can the setting be
effective.
Only when the level of the information type to be outputted is higher than or
equal to the preset value, can the information be allowed to be outputted to the
corresponding log host.
You can set the operation focusing on information types, and operate multiple
information types simultaneously.
Example: Set all the information output control levels to log host
"log" as 0:
IAD2000(config)#infolevel syslog log syslog 0 alarm 0
debug 0 diagnose 0 oprlog 0 other 0 stat 0 trace 0
IAD2000(config)#
II.
Description of Principal Parameters
value: Information level value, ranging 0–4 (0 is the lowest level,
and 4 is the highest level). Only when the level of the information
type to be outputted is higher than or equal to the preset value, can
the information be allowed to be sent to the corresponding log host.
Chapter 7 Maintaining System