Huawei IAD108A User Manual page 243

Iad108 series access media gateway (amg)
Table of Contents

Advertisement

User Manual
U-SYS IAD108 Integrated Access Device
V.
Querying Command Execution Result
You can use command show alarm content alarmid to show
whether the alarm is outputted to command line, and to verify the
command execution.
alarmed: Alarm ID, ranging 52–1572886.
Caution:
The settings are effective for all command line terminals, that is, whether an
alarm will be reported to all the terminals or not be reported to any terminal.
The alarm output mask function mentioned here is ineffective for NMS, and NM
terminal will provide other abundant alarm filtration functions.
The setting of alarm output command has no impact on alarm generation. The
alarms generated by the system will still be recorded, and the user can query
the records by using alarm history record query command.
Several alarm output setting methods provided will affect each other, while
whether a certain type of alarms will be outputted depends on the last setting.
The output flag of recovery alarms is the same as that of fault alarms. The
system performs this function automatically. That is, if the user sets an output
flag for the fault alarm, the system will set the corresponding recovery alarm with
the same output flag. In a similar way, when setting the recovery alarm output
flag, the corresponding fault alarm output flag will keep consistent.
Chapter 7 Maintaining System
7-55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iad108eIad108v

Table of Contents