D-Link xstack DGS-3620 series Reference Manual page 1013

Layer 3 managed stackable gigabit switch
Hide thumbs Also See for xstack DGS-3620 series:
Table of Contents

Advertisement

xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
led - (Optional) Display the port LED configuration of power saving.
port - (Optional) Display the port configuration of power saving.
hibernation - (Optional) Display the system hibernation configuration of power saving.
If no parameter is specified, all configurations of power saving will be displayed.
Restrictions
None.
Example
To display the power saving function setting:
DGS-3620-28PC:admin#show power_saving
Command: show power_saving
Function Version: 3.00
Link Detection State: Enabled
Length Detection State: Disabled
Power Saving Configuration On System Hibernation
----------------------------------------------------
State: Disabled
Power Saving Configuration On Port LED
------------------------------------------
State: Disabled
Power Saving Configuration On Port
------------------------------------------
State: Disabled
DGS-3620-28PC:admin#
87-6
config led state
Description
This command is used to configure the LED admin state of all ports. When the port LED admin
state is disabled, the LEDs of all ports are turned off. If the port LED admin state is enabled, the
port LEDs are controlled by the ports' link status.
Format
config led state [enable | disable]
Parameters
enable - Specifies to enable the LED admin state of all ports.
disable - Specifies to disable the LED admin state of all ports.