RDL-3000 FAMILY

Redundancy Configuration (SC only)

Use the following settings to configure the 1+1 redundancy option for the sector
controller. This feature is enabled by the options key.
Redundancy Role: Choose the role for this sector controller.
None: Redundancy mode is disabled.
Primary: This unit is Backup and peer Primary SC is active.
Backup: This unit is Primary and peer Backup SC is active.
Peer IP Address: Enter the IP address of the peer sector controller (Primary/Backup).
Timeouts[s]: Enter the period to wait when no response is received from the peer SC.
Notes:
Backup SC determines the state of the Primary SC by monitoring IP connectivity
1.
(does not monitor the wireless state of the Primary SC).
Reboot the active Backup SC to switch back to Primary SC.
2.
Primary SC waits 30 seconds following reboot to determine if Backup SC is active.
3.
Backup SC waits 45 seconds following reboot to determine if Backup SC is active.
4.
System detects multiple Primary or Backup peers (log message).
5.
Controls
Apply: Click to accept and activate the wireless settings displayed on this screen.
Apply & Save All: Click to permanently save the wireless settings displayed on this
screen. Saved settings are restored on power-up, reboot, or at the end of a test cycle.
70-00158-01-08
USER MANUAL

Fig. 39: Web - Redundancy Configuration

Proprietary Redline Communications © 2011