RDL-3000 FAMILY

3.4 Status Screens

3.4.1

General Information

The General Information screen displays system and the Ethernet interface details. Click
to expand fields and

System

System Name: Operator assigned name identifying this unit.
System Details: Additional operator-entered details describing this unit.
System Location: information about the location of this unit.
Contact: Operator-entered contact information for this unit.
System S/N: Serial number of this unit.
Radio Type: Type of radio installed (see
System Mode: The system modes are enabled by the active options key:
PMP SC: This unit is configured as a sector controller. The unit automatically begins
transmitting poll messages to locate and register remote subscribers.
PMP SS: This unit is configured to operate as a subscriber. The unit monitors the
selected RF channel(s) for poll poll messages from a sector controller.
Software Version: Firmware version in use.
Time Since System Start: Elapsed time since the last system reboot/power-cycle.
Start Up Time: Date and time of the last system reboot/powered-cycle. Supported only
when SNTP feature is enabled.
70-00158-01-08
USER MANUAL
to hide fields.

Fig. 20: Web - General Information Screen

Proprietary Redline Communications © 2011
Technical
Specifications).