Status Code Definitions; Working With System Parameters; Parameters Overview; Table 21: Diag. - Pmp Status Code Bits - Redline RDL-3000 SC User Manual

Rdl-3000 family broadband wireless radio platforms
Hide thumbs Also See for RDL-3000 SC:
Table of Contents

Advertisement

RDL-3000 FAMILY

5.3 Status Code Definitions

The status code displays the current alarm conditions as a series of hexadecimal
characters. The bit set to '1' indicates the associated condition is active. All unused bits
are set to zero. To determine the status, the hexadecimal number must be converted to
binary notation.
For example, if 'Radio Over Temperature' (bit 1) and '
wireless MAC
0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
Status Condition
Radio temperature too high
PLL Errors
Firmware Error
No Ethernet packets received
by the wireless MAC
MAC Internal Errors

5.4 Working with System Parameters

The RDL-3000 is a highly configurable communications device. This section describes
how to view, modify, test, and save parameter settings.

Parameters Overview

The RDL-3000 maintains the following sets of parameters:
Parameter Set
Runtime
Parameters
Editing Copy of
Parameters
Saved
Parameters
TFTP Server
Factory Default
Parameters
70-00158-01-08
USER MANUAL
' (bit 16) are active, the status code value would be Hex '12' (0001 0001).

Table 21: Diag. - PMP Status Code Bits

0000
0
0

Table 22: Diag. - Status Codes

17, 18, 19, 20, 21, 22, 23, 24,

Table 23: Diag. - Parameters Overview

Description
Currently active system settings. These values are loaded from 'Saved
Parameters' at system reboot.
These values are loaded from 'Saved Parameters' at system reboot. The
operator can use the Web or CLI interface to modify these values. Activate
changes by using the 'apply' function. Save changes permanently by using
the 'save' functions.
These values are saved in non volatile RAM and are loaded at reboot. Use
the 'save' function to overwrite the last saved settings with the current
contents of the 'Editing Copy of Parameters'. A separate copy of Saved
Parameters is maintained for each firmware version (Active and Alternative).
The 'Runtime Parameters' can be saved to a file on a TFTP server. Settings
are saved as CLI commands in a text file.
Saved configurations can be loaded directly from a file.
Load these settings to restore the RDL-3000 to a known state.
Proprietary Redline Communications © 2011
No Ethernet packets received by the
0
0
Bit
1
4
5
6
8
16
25, 26, 27, 28
Page
0000
0
0
8
7
6
5
4
3
2
Hex
0000 0002
0000 0010
0000 0020
0000 0040
0000 0100
0001 0000
0002 0000 to
1000 0000
125
of 150
December 7, 2011
0
1 0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdl-3000 suRdl-3000 mEnterprise

Table of Contents