Radio Frequency Safety / Sécurité Des Fréquences Radio; Electrical Safety; Electrical Safety Compliance / Conformité À La Sécurité Electrique; Ul Information - Redline RDL-3000 SC User Manual

Rdl-3000 family broadband wireless radio platforms
Hide thumbs Also See for RDL-3000 SC:
Table of Contents

Advertisement

RDL-3000 FAMILY
Radio Frequency Safety / Sécurité des Fréquences Radio
The installer of this radio equipment must ensure that the antenna is located or pointed
such that it does not emit RF fields in excess of the general population limits as defined
by FCC CFR 47, Part 2.1091, Radiofrequency radiation exposure evaluation for fixed
devices & Health Canada limits for the general population; consult Safety Code 6,
obtainable from Health Canada's website:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-eng.php
Le programme d'installation de cet équipement radio doit s'assurer que l'antenne est
située ou orientée de façon à ne pas émettre des champs RF au-delà de la population
en général des limites telles que définies par la FCC CFR 47, partie 2,1091, l'évaluation
par radiofréquence exposition aux rayonnements pour les appareils fixes et de Santé
Canada limites pour la population en général, consulter le Code de sécurité 6, disponible
sur site Web de Santé Canada:
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct-fra.php

Electrical Safety

The equipment meets the requirements for class I EN 60950 (protection against electric
shock).
All external circuits are TNV-1 (as defined in EN 60950).
All equipment must be grounded before the power cable is connected.
For electrical safety the DC power supply shall have reinforced insulation to the mains
supply.
Electrical Safety Compliance / Conformité à la Sécurité Electrique
The RDL-3000 hardware has been tested for compliance to the electrical safety
specifications listed in the following table:
Class I
All External Circuits
All equipment must be grounded
Le RDL-3000 du matériel a été testé pour la conformité aux normes de sécurité
électriques indiquées dans le tableau suivant:
Classe I
Tous les circuits externes
Tous les équipements doivent être mis à la terre

UL Information

The suitability of the supplied Ethernet cable is subject to the approval of Authority
1.
Having Jurisdiction and must comply with the local electrical code.
The equipment must be properly grounded according with NEC and other local
2.
safety code and building code requirements
To meet the over-voltage safety requirements on the telecommunications cables, a
3.
minimum 26 AWG telecommunication line cord must be used.
70-00158-01-08
USER MANUAL

Table 1: Notice - Electrical safety specifications

Table 2: Avis - Spécifications de sécurité électrique
Proprietary Redline Communications © 2011
EN 60950
TNV-1 as defined in EN 60950
EN 60950
TRT-1 tel que défini dans la norme EN
60950
Page
14
of 150
.
.
December 7, 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdl-3000 suRdl-3000 mEnterprise

Table of Contents