2 Instruction Descriptions
• You can execute a maximum of 32 of the following instructions at the same time: SktUDPCreate,
SktUDPRcv, SktUDPSend, SktTCPAccept, SktTCPConnect, SktTCPRcv, SktTCPSend, SktGetTCP-
Status, SktClose, SktClearBuf, and SktSetOption.
• An error occurs in the following cases. Error will change to TRUE.
• There is a setting error for the local IP address.
• The value of a member of Socket is outside of the valid range.
• Data transmission is in progress for the socket specified with Socket.
• The socket specified with Socket is not open.
• The remote node for Socket was specified with a domain name and address resolution failed.
• The handle specified by Socket.Handle does not exist.
• The value of Size exceeds the number of elements in SendDat[].
Sample Programming
Refer to the sample programming that is provided for the SktUDPCreate instruction (page 2-1045).