2 Instruction Descriptions
 Contents of Inline ST2
MVHeatTime := MULTIME(CtlPrd_Heat,(MV_Heat/100));
MVCoolTime := MULTIME(CtlPrd_Cool,(MV_Cool/100));
 Contents of Inline ST3
// Create output values to touch panel.
PTOut_PV := PV;
PTOut_ATDone := PIDAT_HeatCool_inst.ATDone;
PTOut_ATBusy := PIDAT_HeatCool_inst.ATBusy;
PTOut_Error

PTOut_MV

PTOut_MVHeat := PIDAT_HeatCool_inst.MV_Heat;
PTOut_MVCool := PIDAT_HeatCool_inst.MV_Cool;
PT_PB_Heat := PB_Heat;
PT_TI_Heat := TimeToNanoSec( TI_Heat )/1000000;
PT_TD_Heat := TimeToNanoSec( TD_Heat )/1000000;
PT_PB_Cool := PB_Cool;
PT_TI_Cool := TimeToNanoSec( TI_Cool )/1000000;
PT_TD_Cool := TimeToNanoSec( TD_Cool )/1000000;
PT_ManMV := ManMV;
2-722
:= PIDAT_HeatCool_inst.Error;
:= PIDAT_HeatCool_inst.MV;