Ny-Series Instructions Reference Manual (W560 - Omron NY532-5400 Reference Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

ST
Variable
Trigger
LastTrigger
OperatingStart
Operating
ResetPLCError_instance ResetPLCError
// Detect when Trigger changes to TRUE.
IF ( (Trigger=TRUE) AND (LastTrigger=FALSE) ) THEN
OperatingStart:=TRUE;
Operating
END_IF;
LastTrigger:=Trigger;
// Initialize ResetPLCError_instance.
IF (OperatingStart=TRUE) THEN
ResetPLCError_instance(Execute:=FALSE);
OperatingStart:=FALSE;
END_IF;
// Execute ResetPLCError instruction.
IF (Operating=TRUE) THEN
ResetPLCError_instance(Execute:=TRUE);
IF (ResetPLCError_instance.Done=TRUE) THEN
// Processing after normal end
Operating:=FALSE;
END_IF;
IF (ResetPLCError_instance.Error=TRUE) THEN
// Processing after error end
Operating:=FALSE;
END_IF;
END_IF;

NY-series Instructions Reference Manual (W560)

Data type
BOOL
BOOL
BOOL
BOOL
:=TRUE;
2 Instruction Descriptions
Initial value
FALSE
Execution condition
Value of Trigger from previous
FALSE
task period
FALSE
Processing started
FALSE
Processing
Comment
2
2-817