ST
Name
index
UINT
LimitAlarm_ON
BOOL
LimitAlarmDv_ON
BOOL
TimeProportionalO
BOOL
ut_ON
AI
INT
PV
ARRAY[0..3] OF REAL
SP
ARRAY[0..3] OF REAL
DOut_TPO
BOOL
HighVal
ARRAY[0..3] OF REAL
LowVal
ARRAY[0..3] OF REAL
Hystrs_LimitAlarm
ARRAY[0..3] OF REAL
Q_LimitAlarm
ARRAY[0..3] OF BOOL
HighAlm
ARRAY[0..3] OF BOOL
LowAlm
ARRAY[0..3] OF BOOL
Error_LimitAlarm
ARRAY[0..3] OF BOOL
Alm_LimitAlarm
ARRAY[0..3] OF BOOL
DvHighVal
ARRAY[0..3] OF REAL
DvLowVal
ARRAY[0..3] OF REAL
Q_LimitAlarmDv
ARRAY[0..3] OF BOOL
HighAlmDv
ARRAY[0..3] OF BOOL
LowAlmDv
ARRAY[0..3] OF BOOL
Error_LimitAlarmDv
ARRAY[0..3] OF BOOL
Hystrs_LimitAlarmDv ARRAY[0..3] OF REAL
Alm_LimitAlarmDv
ARRAY[0..3] OF BOOL
Run
ARRAY[0..3] OF BOOL
ManCtl
ARRAY[0..3] OF BOOL
StartAT
ARRAY[0..3] OF BOOL
NY-series Instructions Reference Manual (W560)
Data type
0
True
True
True
0
[4(0.0)]
[4(100)]
False
[4(200)]
[4(0.0)]
[4(5)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
[4(50)]
[4(50)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
[4(3)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
2 Instruction Descriptions
Default
Retain
Comment
Loop index
Execution of
Upper/Lower Limit
Alarm instruction
Execution of
Upper/Lower Devia-
tion Alarm instruction
Execution of Time-
proportional Output
instruction
Present value
Process value
Set point
Time-proportional
output
Upper limit set value of
upper/lower limit alarm
Lower limit set value of
upper/lower limit alarm
Hysteresis of
upper/lower limit alarm
Upper/lower limit alarm
output
Upper limit alarm
Lower limit alarm
Error in LimitAlarm_-
REAL instruction
Output for safety mea-
sure for Upper/Lower
Limit Alarm instruction
Upper deviation set
value of upper/lower
deviation alarm
Lower deviation set
value of upper/lower
deviation alarm
Upper/lower deviation
alarm output
Upper deviation alarm
Lower deviation alarm
Error in LimitAlarmDv_-
REAL instruction
Hysteresis of
upper/lower deviation
alarm
Output for safety mea-
sure for Upper/Lower
Deviation Alarm
instruction
Execution condition
Manual/auto control
Autotuning execution
condition
2-739