Ny-Series Instructions Reference Manual (W560 - Omron NY532-5400 Reference Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

2 Instruction Descriptions
Name
LowVal
ARRAY[0..3] OF REAL
Hystrs_LimitAlarm ARRAY[0..3] OF REAL
Q_LimitAlarm
ARRAY[0..3] OF BOOL
HighAlm
ARRAY[0..3] OF BOOL
LowAlm
ARRAY[0..3] OF BOOL
Error_LimitAlarm
ARRAY[0..3] OF BOOL
Alm_LimitAlarm
ARRAY[0..3] OF BOOL
DvHighVal
ARRAY[0..3] OF REAL
DvLowVal
ARRAY[0..3] OF REAL
Q_LimitAlarmDv
ARRAY[0..3] OF BOOL
HighAlmDv
ARRAY[0..3] OF BOOL
LowAlmDv
ARRAY[0..3] OF BOOL
Error_LimitA-
ARRAY[0..3] OF BOOL
larmDv
Hystrs_LimitA-
ARRAY[0..3] OF REAL
larmDv
Alm_LimitA-
ARRAY[0..3] OF BOOL
larmDv
Run
ARRAY[0..3] OF BOOL
ManCtl
ARRAY[0..3] OF BOOL
StartAT
ARRAY[0..3] OF BOOL
OprSetParams
_sOPR_SET_PARAMS
InitSetParams
_sINIT_SET_PARAMS
PB
ARRAY[0..3] OF REAL
TI
ARRAY[0..3] OF TIME
TD
ARRAY[0..3] OF TIME
ManMV
ARRAY[0..3] OF REAL
ATDone
ARRAY[0..3] OF BOOL
ATBusy
ARRAY[0..3] OF BOOL
Error_PIDAT
ARRAY[0..3] OF BOOL
ErrorID
ARRAY[0..3] OF WORD
2-736
Data type
[4(0.0)]
[4(5)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
[4(50)]
[4(50)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
[4(3)]
[4(False)]
[4(False)]
[4(False)]
[4(False)]
(MVLowLmt:=0.0, MVUpLmt:=100.0,
ManResetVal:=0.0, MVTrackSw:=False,
MVTrackVal:=0.0, StopMV:=0.0,
ErrorMV:=0.0, Alpha:=0.65,
ATCalcGain:=1.0, ATHystrs:=0.2)
(SampTime:=T#100ms, RngLowLmt:=−10.0,
RngUpLmt:=1000.0, DirOpr:=False)
[4(10)]
[4(T#0S)]
[4(T#0S)]
[4(0.0)]
[4(False)]
[4(False)]
[4(False)]
[4(16#0)]
Default
Retain

NY-series Instructions Reference Manual (W560)

Comment
Lower limit set value of
upper/lower limit alarm
Hysteresis of
upper/lower limit alarm
Upper/lower limit alarm
output
Upper limit alarm
Lower limit alarm
Error in LimitAlarm_-
REAL instruction
Output for safety mea-
sure for Upper/Lower
Limit Alarm instruction
Upper deviation set
value of upper/lower
deviation alarm
Lower deviation set
value of upper/lower
deviation alarm
Upper/lower deviation
alarm output
Upper deviation alarm
Lower deviation alarm
Error in LimitAlarmDv_-
REAL instruction
Hysteresis of
upper/lower deviation
alarm
Output for safety mea-
sure for Upper/Lower
Deviation Alarm
instruction
Execution condition
Manual/auto control
Autotuning execution
condition
Operation setting
parameters
Initial setting parame-
ters
Proportional band
Integration time
Derivative time
Manual manipulated
variable
Autotuning normal
completion
Autotuning busy
Error in PIDAT instruc-
tion
Error ID for PIDAT
instruction