Ny-Series Instructions Reference Manual (W560 - Omron NY532-5400 Reference Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

2 Instruction Descriptions
The ResetAlarm instruction resets the user-defined error specified by event code Code.
Also an event is recorded in the user-defined event log area to show that a specific user-defined error was reset.
Event code
Code
Event code: 65533
Event level: User information
Related System-defined Variables
Name
_AlarmFlag
*1 Refer to the NJ/NX-series CPU Unit Software User's Manual (Cat. No. W501) or NY-series Industrial Panel PC / Industrial
Box PC Software User's Manual (Cat. No. W558) for details.
Precautions for Correct Use
• An error does not occur if the user-defined error specified by Code has not occurred.
• Return value Out is not used when the instruction is used in ST.
• An error occurs in the following case. ENO will be FALSE.
• The value of Code is outside of the valid range.
Sample Programming
Refer to the sample programming that is provided for the SetAlarm instruction (page 2-806).
2-812
UINT#101
Written.
Meaning
Error Status of User-
WORD
defined Errors
User-defined error is reset.
User-defined Event Log Area
Data type
These flags indicate when user-defined errors
are detected.
Bit 0 to bit 7 indicate the status of user-defined
error levels 1 to 8.

NY-series Instructions Reference Manual (W560)

Description
*1