2 Instruction Descriptions

RestartNXUnit

The RestartNXUnit instruction restarts an EtherCAT Coupler Unit or NX Unit.
Instruction
Name
RestartNXUnit
Restart NX
Units
Variables
Name
Meaning
UnitProxy
Specified Unit
* If you omit the input parameter, the default value is not applied.
Bit strings
UnitProxy
Function
The RestartNXUnit instruction restarts an EtherCAT Coupler Unit or an NX Unit on the EtherCAT Cou-
pler Unit, and an NX Unit connected to the NX bus on the NX Bus Function Module or on the CPU Unit.
You can use it to restart a specified Unit independently.
However, you cannot restart an EtherCAT Coupler Unit or NX Bus Function Module independently.
If you specify an EtherCAT Coupler Unit or NX Bus Function Module, all of the NX Units that are con-
nected to it are also restarted.
The Unit to restart is specified with UnitProxy.
2-836
FB/FUN
Graphic expression
FB
RestartNXUnit_instance
Execute
UnitProxy
I/O
Description
Input
A Unit to restart: EtherCAT Cou-
pler Unit, NX Bus Function Mod-
ule or NX Unit
Integers
Refer to Function for details on the structure _sNXUNIT_ID.
RestartNXUnit_instance(Execute,
UnitProxy, Done, Busy, Error,
RestartNXUnit
ErrorID, ErrorIDEx);
Done
Busy
Error
ErrorID
ErrorIDEx
Valid range
---
A building error will occur.
NY-series Instructions Reference Manual (W560)
ST expression