Ny-Series Instructions Reference Manual (W560 - Omron NY532-5400 Reference Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

2 Instruction Descriptions
Therefore, the following figure shows the output operation for the following values of the elements of
the two arrays.
Name
OnTime[]
OffTime[]
TRUE
Output
FALSE
 When Value of One Element in OnTime[] and OffTime[] Is 0
If the value of the element in OnTime[] or OffTime[] is 0, the value of the output will change to TRUE
or FALSE immediately after execution of the instruction.
If the only the value of the element in OnTime[] is 0, the value of the output will change to TRUE
immediately after execution of the instruction. Therefore, the following figure shows the output oper-
ation for the following values of the elements of the two arrays.
Name
OnTime[]
OffTime[]
TRUE
Output
FALSE
If the only the value of the element in OffTime[] is 0, the value of the output will change to FALSE
immediately after execution of the instruction. Therefore, the following figure shows the output oper-
ation for the following values of the elements of the two arrays.
Name
OnTime[]
OffTime[]
2-1350
Element numbers
0
1
20 ms later
35 ms later
10 ms later
30 ms later
Reference time
10 ms
20 ms
30 ms
35 ms
Element numbers
0
1
0
30 ms later
20 ms later
35 ms later
Reference time
20 ms
30 ms
35 ms
Element numbers
0
1
10 ms later
35 ms later
0
30 ms later
2
0
0
2
0
0
2
0
0

NY-series Instructions Reference Manual (W560)