2 Instruction Descriptions
• Error is TRUE if an error occurred. The meanings of the values of ErrorID and ErrorIDEx are given in
the following table.
Value of
ErrorID
16#0400
16#0419
16#041B
16#2C00
2-950
Value of ErrorI-
DEx
• The value of UnitProxy is outside of the valid range.
16#0000 0000
• The value of TimeOut is outside of the valid range.
• The data type of UnitProxy is not correct.
16#0000 0000
• The data type of WriteDat is not correct.
16#0000 0000
More than 2,048 bytes of data was specified for WriteDat.
16#0000 0401
The specified Unit does not support the instruction.
16#0000 1001
An input parameter, output parameter, or in-out parameter is incorrect.
16#0000 1002
Confirm that the intended parameter is used for the input parameter, out-
16#0017 0000
put parameter, or in-out parameter.
16#0020 0000
16#0021 0000
The data size of the specified NX object does not agree with the data
16#0000 1010
size specified in WriteDat.
The correct Unit was not specified.
16#0000 1101
Check the Unit.
The size of the read data is too large.
16#0000 110B
Make sure that the read data specification is correct.
16#0000 1110
There is no object that corresponds to the value of Obj.Index.
16#0000 1111
There is no object that corresponds to the value of Obj.Subindex.
16#0000 2101
The specified NX object cannot be written.
The value of WriteDat exceeds the range of the values of the NX object
16#0000 2110
to write.
16#0000 2210
The specified Unit is not in a mode that allows writing data.
Instruction execution was not possible because the specified Unit was
16#0000 2213
performing an I/O check.
Execute the instruction after the I/O check is completed.
The status of the specified Unit does not agree with the value of the read
source or write destination NX object.
Take the following actions if the value of Obj.Index is between 0x6000
and 0x6FFF or between 0x7000 and 0x7FFF.
16#0000 2230
• Delete the read source or write designation NX object from the I/O
allocation settings.
• Reset the error for the specified Unit.
• Place the specified Unit in a mode that does not allow writing data.
Instruction execution was not possible because the specified Unit was
performing initialization.
16#0000 2231
Wait for the Unit to start normal operation and then execute the instruc-
tion.
Hardware access failed.
16#0000 250F
Execute the instruction again.
16#0000 2601
The specified Unit does not support this instruction.
16#0000 2602
Check the version of the Unit.
16#0010 0000
Execution of the instruction failed.
Execute the instruction again.
16#0000 2603
Make sure that at least one channel is enabled in the selections of the
channels to use.
The NX Unit is not in a status in which it can acknowledge the instruc-
16#0000 2621
tion.
Wait for a while and then execute the instruction again.
The specified Unit does not exist.
16#0001 0000
Make sure that the Unit configuration is correct.
The specified port number does not exist.
16#00110000
Make sure that the Unit configuration is correct.