Ny-Series Instructions Reference Manual (W560 - Omron NY532-5400 Reference Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Exter-
nal Vari-
ables
E001_NX_Unit_I_O_Data_Ac-
tive_Status_63
N1_Node_location_information _sNXUNIT_ID
// Detection of SetER or ResetER
IF (NX_SerialSigCtl_instance.Done OR NX_SerialSigCtl_instance.Error) THEN
OperatingStart:=FALSE;
ELSE_IF
OperatingStart:=(SetER OR ResetER)
tus_63[1]
DevicePort.DeviceType:=_eDEVICE_TYPE#_DeviceNXUnit;
DevicePort.NxUnit:=N1_Node_location_information;
DevicePort.PortNo:=2;
END_IF;
// ER signal value is determined.
CfgValue(Set:=SetER, Reset1:=ResetER);
// NX_SerialSigCtl instruction is executed.
NX_SerialSigCtl_instance(Execute:=OperatingStart,

NY-series Instructions Reference Manual (W560)

Name
Data type
ARRAY[0..63]
OF BOOL
DevicePort:=DevicePort,
Kind:=_eSERIAL_SIG#_SIG_ER,
Sig:=CfgValue.Q1);
2 Instruction Descriptions
Comment
• Usage of I/O data for 63 NX Units.
• If the relevant Unit number is 1, E001_NX-
_Unit_I_O_Data_Active_Status_63[1] is used.
Device variable to specify NX-CIF210
AND E001_NX_Unit_I_O_Data_Active_Sta-
AND NOT(P_FirstRun);
2
2-1223

Hide quick links:

Advertisement

Table of Contents
loading