2 Instruction Descriptions
Refer to the Sysmac Studio Version 1 Operation Manual (Cat. No. W504-E1-07 or later) for details on
assigning a device variable to the node location information.
Use PortNo to specify the port number.
1: Port 1
2: Port 2
The data type of DeviceType is enumerated type _eDEVICE_TYPE.
The meanings of the enumerators of enumerated type _eDEVICE_TYPE are as follows:
Enumerator
_DeviceNXUnit
_DeviceEcatSlave
_DeviceOptionBoard
In this instruction, you can specify _DeviceNXUnit.
When the Continuous input variable is TRUE, continuous monitoring is selected and the monitoring is
continued until the NX_SerialStopMon instruction is executed.
When the Continuous input variable is FALSE, one-shot monitoring is selected and serial line monitor-
ing is continued until the buffer becomes full or the NX_SerialStopMon instruction is executed.
An error occurs if this instruction is executed for Units other than NX-series Communications Interface
Units.
Timing Charts
The following figures show the timing charts.
2-1236
Meaning
NX Unit is specified.
EtherCAT slave is specified.
Option Board is specified.
Assign a variable.
Do not assign variables.