Programming Example; Preparatory Operations - Omron CPM2C-S100C Operation Manual

Sysmac cpm2c-s series
Table of Contents

Advertisement

Programming Example

8-3

Programming Example

8-3-1

Preparatory Operations

1,2,3...
!Caution Check the system thoroughly before starting or stopping the CPM2C-S to pre-
This section demonstrates all of the steps needed to write a program with the
Programming Console.
Use the following procedure when writing a program to the CPM2C-S for the
first time.
1. Set the Programming Console's mode switch to PROGRAM mode and
turn on the CPM2C-S' power supply. The password input display will ap-
pear on the Programming Console.
MONITOR
RUN
PROGRAM
2. Enter the password by pressing the CLR and then the MONTR Key.
CLR
MONTR
3. Clear the CPM2C-S' memory by pressing the CLR, SET, NOT, RESET, and
then the MONTR Key. Press the CLR Key several times if memory errors
are displayed.
SET
NOT
RESET
MONTR
4. Display and clear error messages by pressing the CLR, FUN, and then the
MONTR Key. Continue pressing the MONTR Key until all error messages
have been cleared.
MONTR
5. Press the CLR Key to bring up the initial programming display (program ad-
dress 00000). The new program can be written at this point.
vent any accidents that might occur when the program is first started.
<PROGRAM>
PASSWORD!
<PROGRAM>

CLR
MEMORY CLR?
HR CNT DM
00000MEMORY CLR
END HR CNT DM

CLR

FUN (0??)
FUN
ERR/MSG CHK OK

CLR
Section 8-3
BZ
193

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpm2c-s110cCpm2c-s100c-drtCpm2c-s110c-drt

Table of Contents