Reading/Clearing Error Messages - Omron CPM2C-S100C Operation Manual

Sysmac cpm2c-s series
Table of Contents

Advertisement

Programming Console Operations
8-2-5

Reading/Clearing Error Messages

Key Sequence
1,2,3...
area, refer to the CX-Programmer (version 2.0 or later) Operation Manual
(W414).
RUN
OK
OK
VRFY
FUN
CLR
This operation is used to display and clear error messages. It is possible to
display and clear non-fatal errors and MESSAGE instruction messages in any
mode, but fatal errors can be cleared in PROGRAM mode only.
RUN
OK
OK
Before inputting a new program, any error messages recorded in memory
should be cleared. It is assumed here that the causes of any of the errors for
which error messages appear have already been taken care of. If the buzzer
sounds when an attempt is made to clear an error message, eliminate the
cause of the error, and then clear the error message. (Refer to SECTION 9
Test Runs and Error Processing for troubleshooting information.)
Follow the procedure below to display and clear messages.
1. Press the CLR Key to bring up the initial display.
2. Press the FUN and then the MONTR Key to begin the operation. If there
are no messages, the following display will appear:
FUN
MONTR
If there are messages, the most serious message will be displayed when
the MONTR Key is pressed. Pressing MONTR again will clear the present
message and display the next most serious error message. Continue
pressing MONTR until all messages have been cleared. These are some
examples of error messages:
A memory error:
MONTR
A system error:
MONTR
A message (displayed with MSG(46)):
MONTR
MONITOR
PROGRAM
OK
CA LAD
02 04.1
I/O comment area:
2 Kwords
(truncated display
of 2,048 words)
MONITOR
PROGRAM
OK
ERR/MSG CHK OK
MEMORY ERR
SYS FAIL FAL01
MATERIAL USED UP
Section 8-2
Ladder program area:
4.1 Kwords (rounded-off
display of 4,096 words)