Restoring parameter defaults

Restoring parameter defaults by this method saves the default values in
the drives memory. User security status (Pr 10) and User security code
(Pr 25) are not affected by this procedure).
Procedure
1. Ensure the drive is not enabled, i.e. drive is in inhibit or under
voltage state.
2. Select 'Def.50' or 'Def.60' in Pr 00 or Pr mm.000. (alternatively, enter
1233 (50 Hz settings) or 1244 (60 Hz settings) in Pr 00 or
Pr mm.000).
3. Either:
Press the red
reset button
Carry out a drive reset through serial communications by setting
Pr 10.038 to 100
5.9

Parameter access level and security

The parameter access level determines whether the user has access to
Menu 0 only or to all the advanced menus (Menus 1 to 24) in addition to
Menu 0.
The User Security determines whether the access to the user is read
only or read write.
Both the User Security and Parameter Access Level can operate
independently of each other as shown in Table 5-5.
Table 5-5 Parameter access level and security
User
security
Access
status
level
(Pr 10)
0
LEVEL.1
RW
1
LEVEL.2
RW
2
ALL
RW
3
StAtUS
RW
4
no.Acc
RW
The default settings of the drive are Parameter Access Level LEVEL.1
and user Security Open i.e. read / write access to Menu 0 with the
advanced menus not visible.
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
Advanced menu
Menu 0 status
status
Not visible
Not visible
RW
Not visible
Not visible
Running the
NV Media
Optimization
motor
Card
5.9.1
User Security Level / Access Level
The drive provides a number of different levels of security that can be set
by the user via User Security Status (Pr 10); these are shown in the table
below.
User Security
Status
(Pr 10)
LEVEL.1 (0)
Access to first 10 parameters in Menu 0 only.
LEVEL.2 (1)
Access to all parameters in Menu 0.
ALL (2)
Access to all menus.
The keypad remains in status mode and only first 10
StAtUS (3)
parameters in Menu 0 can be viewed or edited.
The keypad remains in status mode and only first 10
parameters in Menu 0 can be viewed or edited. Drive
no.Acc (4)
parameters cannot be accessed via a comms
interface.
5.9.2
Changing the User Security Level /Access
Level
The security level is determined by the setting of Pr 10 or Pr 11.044. The
Security Level can be changed through the keypad even if the User
Security Code has been set.
5.9.3
User Security Code
The User Security Code, when set, prevents write access to any of the
parameters in any menu.
Setting User Security Code
Enter a value between 1 and 9999 in Pr 25 and press the
button; the security code has now been set to this value. In order to
activate the security, the Security level must be set to desired level in
Pr 10. When the drive is reset, the security code will have been activated
and the drive returns to LEVEL.1. The value of Pr 25 will return to 0 in
order to hide the security code.
Unlocking User Security Code
Select a parameter that need to be edited and press the
the display will now show 'Co'. Use the arrow buttons to set the security
code and press the
entered, the display will revert to the parameter selected in edit mode.
If an incorrect security code is entered, the following message 'Co.Err' is
displayed, and the display will revert to parameter view mode.
Disabling User Security
Unlock the previously set security code as detailed above. Set Pr 25 to 0
and press the
disabled, and will not have to be unlocked each time the drive is
powered up to allow read / write access to the parameters.
5.10
Displaying parameters with non-
default values only
By selecting 'diff.d' in Pr 00 (Alternatively, enter 12000 in
Pr 00), the only parameters that will be visible to the user will be those
containing a non-default value. This function does not require a drive
reset to become active. In order to deactivate this function, return to
Pr 00 and select 'none' (alternatively enter a value of 0). Please note that
this function can be affected by the access level enabled, refer to section
5.9 Parameter access level and security on page 27 for further
information regarding access level.
Onboard
Advanced
Diagnostics
PLC
parameters
Description
button. With the correct security code
button. The User Security has now been
UL Listing
button,
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents