Parameter
06.001
Stop Mode
06.002
Limit Switch Stop Mode
06.003
Supply Loss Mode
06.004
Start/Stop Logic Select
06.006
Injection Braking Level
06.007
Injection Braking Time
06.008
Hold Zero Frequency
06.009
Catch A Spinning Motor
06.010
Enable Conditions
06.011
Sequencer State Machine Inputs
06.012
Enable Stop Key
06.013
Enable Auxiliary Key
06.014
Disable Auto Reset On Enable
06.015
Drive Enable
06.016
Date
06.017
Time
06.018
Day Of Week
06.019
Date/Time Selector
06.020
Date Format
06.021
Time Between Filter Changes
Filter Change Required /
06.022
Change Done
06.023
Time Before Filter Change Due
06.024
Reset Energy Meter
06.025
Energy Meter: MWh
06.026
Energy Meter: kWh
06.027
Energy Cost Per kWh
06.028
Running Cost
06.029
Hardware Enable
06.030
Run Forward
06.031
Jog Forward
06.032
Run Reverse
06.033
Forward/Reverse
06.034
Run
06.035
Forward Limit Switch
06.036
Reverse Limit Switch
06.037
Jog Reverse
06.038
User Enable
06.039
Not Stop
06.040
Enable Sequencer Latching
06.041
Drive Event Flags
06.042
Control Word
06.043
Control Word Enable
06.045
Cooling Fan control
06.047
Input Phase Loss Detection Mode
06.048
Supply Loss Detection Level
06.051
Hold Supply Loss Active
06.052
Motor Pre-heat Current Magnitude
06.058
Output Phase Loss Detection Time
06.059
Output Phase Loss Detection Enable
06.060
Standby Mode Enable
06.061
Standby Mode Mask
06.071
Slow Rectifier Charge Rate Enable
06.073
Braking IGBT Lower Threshold
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
Range ()
OL
CoASt (0), rP (1),
rP.dc I (2), dc I (3),
td.dc I (4),
diS (5)
StoP (0), rP (1)
diS (0), rP.StoP (1), ridE.th (2), Lt.StoP (3)
0 to 6
0.0 to 150.0 %
0.0 to 100.0 s
Off (0) or On (1)
diS (0), EnAbLE (1), Fr.OnLy (2), rv.OnLy (3)
0 to 4087
0 to 127
Off (0) or On (1)
diS (0), Fd.rv (1), rEv (2)
Off (0) or On (1)
Off (0) or On (1)
00-00-00 to 31-12-99
00:00:00 to 23:59:59
Sun (0), Non (1), tuE (2), UEd (3),thu (4),
Fri (5), SAt (6)
SEt (0), Po.uP (1), run (2), Acc.Po (3),
rE.PAd (5), SLot.1 (6)
Std (0), US (1)
0 to 30000 Hours
Off (0) or On (1)
0 to 30000 Hours
Off (0) or On (1)
±999.9 MWh
±99.99 kWh
0.0 to 600.0
± 32000
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
0 to 3
0 to 32767
0 to 1
0 to 5
FuLL (0), rIPPLE (1), diS (2)
0 to VM_SUPPLY_LOSS_LEVEL V
Off (0) or On (1)
0 to 100 %
0.5 (0) to 4 (3) s
Off (0) or On (1)
Off (0) or On (1)
0 to 15
Off (0) or On (1)
0 to VM_DC_VOLTAGE_SET V
Running the
NV Media
Optimization
motor
Card
Default()
RFC-A
OL
CoASt (0), rP (1),
rP.dc I (2), dc I (3),
td.dc I (4),
diS (5), No.rP (6)
110 V drive: 205 V,
200 V drive: 205 V
400 V drive: 410 V,
575 V drive: 540 V
690 V drive: 540 V
110 V drive: 390 V,
200 V drive: 390 V
400 V drive: 780 V,
575 V drive: 930 V
690 V drive: 1120 V
Onboard
Advanced
Diagnostics
PLC
parameters
RFC-A
rP (1)
RW
Txt
rP (1)
RW
Txt
diS (0)
RW
Txt
0
RW
Num
100.0 %
RW
Num
1.0 s
RW
Num
Off (0)
RW
Bit
diS (0)
RW
Txt
RO
Bin
RO
Bin
Off (0)
RW
Bit
diS (0)
RW
Txt
Off (0)
RW
Bit
On (1)
RW
Bit
RW
Date
RW
Time
RO
Txt
Po.uP (1)
RW
Txt
Std (0)
RW
Txt
0 Hours
RW
Num
RW
Bit
RO
Num
Off (0)
RW
Bit
RO
Num
RO
Num
0.0
RW
Num
RO
Num
RO
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
0
RW
Bin
0
RW
Bin
0
RW
Num
2
RW
Num
FuLL (0)
RW
Txt
RW
Num
Off (0)
RW
Bit
0 %
RW
Num
0.5 (0) s
RW
Txt
Off (0)
RW
Bit
Off (0)
RW
Bit
0
RW
Bin
Off (0)
RW
Bit
RW
Num
UL Listing
Type
US
US
US
US
RA
US
US
US
US
ND
NC PT
ND
NC PT
US
US
US
US
ND
NC PT
ND
NC PT
ND
NC PT
US
US
US
ND
NC
ND
NC PT PS
ND
NC PT PS
ND
NC PT PS
US
ND
NC PT
ND
NC PT
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
US
NC
NC
US
US
US
RA
US
NC
US
US
US
US
US
US
RA
US
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents