The dEr.I trip indicates that an error has been detected in the derivative product image. The reason for the trip can be
identified by the sub-trip number.
Sub-trip
1
2
3
4
5
6
7
30
248
31
32
33
34
40
41
51
52
53
61
80
81
Recommended actions:
Contact the supplier of the drive
dESt
Two or more parameters are writing to the same destination parameter
The dest trip indicates that destination parameters of two or more functions (Menus 7, 8, 9, 12 or 14) within the drive are
writing to the same parameter.
199
Recommended actions:
Set Pr 00 to 'dest' or 12001 and check all visible parameters in all menus for parameter write conflicts
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
Reason
Divide by zero
Undefined trip
Attempted fast parameter access set-up with non-existent
parameter
Attempted access to non-existent parameter
Attempted write to read-only parameter
Attempted an over-range write
Attempted read from write-only parameter
The image has failed because either its CRC is incorrect, or
there are less than 6 bytes in the image or the image header
version is less than 5
The image requires more RAM for heap and stack than can be
provided by the drive.
The image requires an OS function call that is higher than the
maximum allowed.
The ID code within the image is not valid
The derivative image has been changed for an image with a
different derivative number
The timed task has not completed in time and has been
suspended
Undefined function called, i.e. a function in the host system
vector table that has not been assigned
Core menu customization table CRC check failed
Customizable menu table CRC check failed
Customizable menu table changed
The option module installed in slot 1 is not allowed with the
derivative image
Image is not compatible with the control board
Image is not compatible with the control board serial number
Running the
NV Media
Optimization
motor
Card
Diagnosis
Occurs when the drive powers-up or the image is
programmed. The image tasks will not run
As 30
As 30
As 30
As 30
Reduce code in timed task or power down repeat
rate.
As 40
As 30
As 30
Occurs when the drive powers-up or the image is
programmed and the table has changed. Defaults
are loaded for the derivative menu and the trip will
keep occurring until drive parameters are saved.
As 30
Initiated from within the image code
As 80
Onboard
Advanced
Diagnostics
PLC
parameters
Comments
UL Listing
133

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents