Menu Structure; Menu 0 - Nidec Unidrive M200 User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Figure 5-4 Mode examples

1

3
1
Parameter view mode: Read write or Read only
2
Status mode: Drive OK status
If the drive is ok and the parameters are not being edited or viewed, the
display will show one of the following:
inh', 'rdy' or status mode parameter value.
3
Status mode: Trip status
When the drive is in trip condition, the display will indicate that the drive
has tripped and the display will show the trip code. For further
information regarding trip codes, refer to section 12.4 Trips, Sub-trip
numbers on page 130.
4
Status mode: Alarm status
During an 'alarm' condition the display flashes between the drive status
parameter value and the alarm.
Do not change parameter values without careful
consideration; incorrect values may cause damage or a
safety hazard.
WARNING
NOTE
When changing the values of parameters, make a note of the new
values in case they need to be entered again.
NOTE
New parameter values must be saved to ensure that the new values
apply after the drive has been power cycled. Refer to section 5.7 Saving
parameters on page 26.
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters

2

4
Running the
NV Media
Optimization
motor
Card
5.3

Menu structure

The drive parameter structure consists of menus and parameters.
The drive initially powers up so that only Menu 0 can be viewed. The up
and down arrow buttons are used to navigate between parameters and
once Pr 10 has been set to 'All' the up and down buttons are used to
navigate between menus.
For further information refer to section 5.9 Parameter access level and
security on page 27.
The menus and parameters rollover in both directions i.e. if the last
parameter is displayed, a further press will cause the display to rollover
and show the first parameter.
When changing between menus, the drive remembers which parameter
was last viewed in a particular menu and thus displays that parameter.
5.4

Menu 0

Menu 0 is used to bring together various commonly used parameters for
basic easy set up of the drive. The parameters displayed in Menu 0 can
be configured in Menu 22.
Appropriate parameters are copied from the advanced menus into Menu
0 and thus exist in both locations.
For further information, refer to Chapter 6 Basic parameters on page 29.
Figure 5-5 Menu 0 copying
Menu 0
04
10.0
05
AV
06
4.1
Onboard
Advanced
Diagnostics
PLC
parameters
Menu 2
02.021
10.0
Menu 11
11.034
Menu 5
05.007
4.1
UL Listing
AV
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents