Nv Media Card Parameters; Nv Media Card Trips; Data Block Header Information - Nidec Unidrive M200 User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
by setting the warning suppression flag. If this flag is set the drive will not
trip if the option module or drive ratings are different between the
source and destination drives. The option module or rating dependent
parameters will not be transferred.
Setting 9666 in Pr 00 will set the warning suppression flag
Setting 9555 in Pr 00 will clear the warning suppression flag
9.2.15
9888 / 9777 - Setting and clearing the NV
Media Card read only flag
The NV Media Card may be protected from writing or erasing by setting
the read only flag. If an attempt is made to write or erase a data block
when the read only flag is set, a 'C.rdo' trip is initiated. When
the read only flag is set only codes 6yyy or 9777 are effective.
Setting 9888 in Pr 00 will set the read only flag
Setting 9777 in Pr 00 will clear the read only flag
9.3

NV Media Card parameters

Table 9-2 Key to parameter table coding
RW
Read / Write
RO
Read only
Num
Number parameter
Bit
Bit parameter
Txt
Text string
Bin
Binary parameter
FI
Filtered
11.036
NV Media Card File Previously Loaded
RO
Num
0 to 999
This parameter shows the number of the data block last transferred from
an SD card to the drive. If defaults are subsequently reloaded this
parameter is set to 0.
11.037
NV Media Card File Number
RW
Num
0 to 999
This parameter should have the data block number which the user would
like the information displayed in Pr 11.038, Pr 11.039.
11.038
NV Media Card File Type
RO
Txt
ND
0 to 2
Displays the type of data block selected with Pr 11.037.
Pr 11.038
String
0
None
1
Open-loop
2
RFC-A
11.039
NV Media Card File Version
RO
Num
ND
0 to 9999
Displays the version number of the file selected in Pr 11.037.
64
Electrical
Getting
Basic
installation
started
parameters
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependant
US
User save
PS
Power-down save
DE
Destination
NC
PT
0
0
NC
PT
0
Type / mode
No file selected
Open loop mode parameter file
RFC-A mode parameter file
NC
PT
0
Running the
NV Media
Optimization
motor
Card
11.042 {30}
Parameter Cloning
RW
Txt
NonE (0), rEAd (1), Prog
(2), Auto (3),
boot (4)
9.4

NV Media Card trips

After an attempt to read, write or erase data from a NV Media Card a trip
is initiated if there has been a problem with the command.
See Chapter 12 Diagnostics on page 129 for more information on NV
Media Card trips.
9.5

Data block header information

Each data block stored on a NV Media Card has header information
detailing the following:
NV Media Card File Number (11.037)
NV Media Card File Type (11.038)
NV Media Card File Version (11.039)
The header information for each data block which has been used can be
viewed in Pr 11.038 to Pr 11.039 by increasing or decreasing the data
block number set in Pr 11.037. If there is no data on the card Pr 11.037
can only have a value of 0.
Onboard
Advanced
Diagnostics
PLC
parameters
NC
Unidrive M200 / M201 Control User Guide
Issue Number: 2
UL Listing
US
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents