Nidec Unidrive M200 User Manual page 107

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
08.001
Digital I/O 1 State (T10)
08.002
Digital Input 2 State (T11)
08.003
Digital Input 3 State (T12)
08.004
Digital Input 4 State (T13)
08.005
Digital Input 5 State (T14)
08.008
Relay 1 Output State
08.011
Digital I/O 1 Invert (T10)
08.012
Digital Input 2 Invert (T11)
08.013
Digital Input 3 Invert (T12)
08.014
Digital Input 4 Invert (T13)
08.015
Digital Input 5 Invert (T14)
08.018
Relay 1 Invert
08.020
Digital I/O Read Word
08.021
Digital IO1 Source / Destination A (T10)
08.022
Digital Input 02 Destination A (T11)
08.023
Digital Input 03 Destination A (T12)
08.024
Digital Input 04 Destination A (T13)
08.025
Digital Input 05 Destination A (T14)
08.028
Relay 1 Output Source A
08.031
Digital I/O 01 Output Mode (T10)
08.035
Digital Input 5 Select (T14)
08.041
Keypad Run Button State
08.042
Keypad Auxiliary Button State
08.043
24 V Supply Input State
08.044
Keypad Stop Button State
08.051
Keypad Run Button Invert / Toggle
08.052
Keypad Auxiliary Button Invert / Toggle
08.053
24 V Supply Input Invert
08.061
Keypad Run Button Destination
08.062
Keypad Auxiliary Button Destination
08.063
24 V Supply Input Destination
08.081
DI1 Control (T10)
08.082
DI2 Control (T11)
08.083
DI3 Control (T12)
08.084
DI4 Control (T13)
08.085
DI5 Control (T14)
08.091
DO1 Control (T10)
08.098
Relay 1 Control
08.121
DI/O 01 Source / Destination B (T10)
08.122
DI 02 Destination B (T11)
08.123
DI 03 Destination B (T12)
08.124
DI 04 Destination B (T13)
08.125
DI 05 Destination B (T14)
08.128
Relay 01 Source B
RW Read / Write
RO
Read only
ND
No default value
NC
Not copied
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
Range ()
OL
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
Not.Inv (0), InvErt (1)
0 to 2048
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
InPut (0), OutPut (1), Fr (2), PuLSE (3)
InPut (0), th.Sct (1), th (2),
th.Notr (3), Fr (4)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Not.Inv (0), InvErt (1), toggLE (2)
Not.Inv (0), InvErt (1), toggLE (2)
Not.Inv (0), InvErt (1),
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0 to 26
0 to 26
0 to 26
0 to 26
0 to 26
0 to 21
0 to 21
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Num Number parameter
PT
Protected parameter
Running the
NV Media
Optimization
motor
Card
Default ()
RFC-A
OL
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
OutPut (1)
InPut (0)
Not.Inv (0)
Not.Inv (0)
Not.Inv (0)
Bit
Bit parameter
Txt
Text string
RA
Rating dependent
US
User save
Onboard
Advanced
Diagnostics
PLC
parameters
RFC-A
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RW
Txt
RW
Txt
RW
Txt
RW
Txt
RW
Txt
RW
Txt
RO
Num
10.003
RW
Num
6.038
RW
Num
6.030
RW
Num
6.032
RW
Num
1.041
RW
Num
10.001
RW
Num
RW
Txt
RW
Txt
RO
Bit
RO
Bit
RO
Bit
RO
Bit
RW
Txt
RW
Txt
RW
Txt
0.000
RW
Num
0.000
RW
Num
0.000
RW
Num
0
RW
Num
0
RW
Num
0
RW
Num
0
RW
Num
0
RW
Num
0
RW
Num
0
RW
Num
RO
Num
RO
Num
RO
Num
RO
Num
RO
Num
0.000
RO
Num
Bin
Binary parameter
PS
Power-down save
UL Listing
Type
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
US
US
US
US
US
US
ND
NC
PT
DE
PT US
DE
PT US
DE
PT US
DE
PT US
DE
PT US
PT US
US
US
ND
NC
PT
ND
NC
PT
ND
NC
PT
ND
NC
PT
US
US
US
DE
PT US
DE
PT US
DE
PT US
US
US
US
US
US
US
US
DE
NC
PT US
DE
NC
PT US
DE
NC
PT US
DE
NC
PT US
DE
NC
PT US
NC
PT US
FI
Filtered
DE
Destination
107

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents