Menu 12: Threshold Detectors, Variable Selectors And Brake Control Function - Nidec Unidrive M200 User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
11.081
Drive Name Characters 9-12
11.082
Drive Name Characters 13-16
11.084
Drive Mode
11.085
Security Status
11.086
Menu Access Status
11.091
Additional Identifier Characters 1
11.092
Additional Identifier Characters 2
11.093
Additional Identifier Characters 3
11.094
Disable String Mode
11.097
AI ID Code
11.098
24V Alarm Loss Enable
11.099
Modbus Parameter Conversion
* With Unidrive M201, the default is PAd (5).
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
IP
IP address
Mac
Mac address
11.13

Menu 12: Threshold detectors, variable selectors and brake control function

Figure 11-19 Menu 12 logic diagram
Threshold
Detector 1
Any variable
parameter
??.???
??.???
Threshold
Detector 2
Any variable
parameter
??.???
??.???
X
X
The parameters are all shown in their default settings
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
OL
OPEn.LP (1), rFC-A (2)
NonE (0), r.onLy.A (1), StAtUS (2),
LEVEL.1 (0), LEVEL.2 (1), ALL (2)
(-2147483648) to (2147483647)
(-2147483648) to (2147483647)
(-2147483648) to (2147483647)
NonE (0), Sd.CArd (1), rS-485 (2),
Num
Number parameter
PT
Protected parameter
Date
Date parameter
Threshold
Detector 1
Level
12.004
Threshold
Detector 1
12.005
12.003
Threshold
Threshold
Detector 1
Detector 1
Source
Hysteresis
Threshold
Detector 2
Level
12.024
Threshold
Detector 2
12.023
12.025
Threshold
Threshold
Detector 2
Detector 2
Source
Hysteresis
Key
Input
X
Read-write (RW)
mm.ppp
terminals
parameter
X
Read-only (RO)
Output
mm.ppp
parameter
terminals
Running the
Optimization
motor
Range ()
RFC-A
(-2147483648) to
(-2147483647)
(-2147483648) to
(-2147483647)
no.Acc (3)
Off (0) or On (1)
boot (3), rS-485 (4)
Off (0) or On (1)
0000 to 1111
Bit
Bit parameter
Txt
Text string
RA
Rating dependent
US
User save
Time
Time parameter
SMP
Slot,menu,parameter
Threshold
Detector 1
Output
12.001
x(-1)
12.006
Threshold
Detector 1
Output Invert
Threshold
Detector 2
Output
12.002
x(-1)
12.026
Threshold
Detector 2
Invert
Threshold
level
Threshold
output
NV Media
Onboard
Advanced
Card
PLC
parameters
Default ()
OL
RFC-A
- - - - (757935405)
RW
Chr
- - - - (757935405)
RW
Chr
RO
Txt
RO
Txt
RO
Txt
RO
Chr
RO
Chr
RO
Chr
Off (0)
RW
Bit
RO
Txt
Off (0)
RW
Bit
0000
RW
Bin
Bin
Binary parameter
PS
Power-down save
Chr
Character parameter
Threshold
Detector 1
Destination
Any
unprotected
12.007
bit parameter
??.???
??.???
Threshold
Detector
2
Destination
Any
unprotected
12.027
bit parameter
??.???
??.???
All parameters are shown
at their default setting
Hysteresis
t
t
Diagnostics
UL Listing
Type
PT
US
PT
US
ND
NC
PT
ND
NC
PT
PS
ND
NC
PT
PS
ND
NC
PT
ND
NC
PT
ND
NC
PT
PT
US
ND
NC
PT
US
US
FI
Filtered
DE
Destination
Ver
Version number
115

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents