Nidec Unidrive M200 User Manual page 72

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M200:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
VM_MAX_SWITCHING_FREQUENCY
Units
User units
Open-loop: 0 (0.667 kHz)
Range of [MIN]
RFC-A: 2 (2 kHz)
Open-loop: 8 (16kHz)
Range of [MAX]
RFC-A: 8 (16kHz)
VM_SWITCHING_FREQUENCY[MAX] = Power stage dependent
VM_SWITCHING_FREQUENCY[MIN] = 0
This variable maximum is used by the Minimum Switching Frequency (05.038) to define the minimum frequency limit
used if the inverter thermal model is actively reducing the switching frequency due to temperature.
Definition
Note that parameter Maximum Switching Frequency (05.018) takes priority over parameter Minimum Switching
Frequency (05.038) so is not limited by parameter Minimum Switching Frequency (05.038). The actual minimum
switching frequency limit used is the lower of Maximum Switching Frequency (05.018) and Minimum Switching
Frequency (05.038).
72
Electrical
Getting
Basic
installation
started
parameters
Range applied to the maximum switching frequency parameters
Running the
NV Media
Optimization
motor
Card
Onboard
Advanced
Diagnostics
PLC
parameters
Unidrive M200 / M201 Control User Guide
Issue Number: 2
UL Listing

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unidrive m201

Table of Contents