FI.In
Firmware Incompatibility
The FI.In trip indicates that the user firmware is incompatible with the power firmware.
237
Recommended actions:
Re-program the drive with the latest version of the drive firmware for Unidrive M200, using Unidrive M Connect.
HF01
Data processing error: CPU hardware fault
The HF01 trip indicates that a CPU address error has occurred. This trip indicates that the control PCB on the drive has
failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF02
Data processing error: CPU memory management fault
The HF02 trip indicates that a DMAC address error has occurred. This trip indicates that the control PCB on the drive has
failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF03
Data processing error: CPU has detected a bus fault
The HF03 trip indicates that a bus fault has occurred. This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF04
Data processing error: CPU has detected a usage fault
The HF04 trip indicates that a usage fault has occurred.This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF05
Reserved
HF06
Reserved
HF07
Data processing error: Watchdog failure
The HF07 trip indicates that a watchdog failure has occurred. This trip indicates that the control PCB on the drive has failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF08
Data processing error: CPU Interrupt crash
The HF08 trip indicates that a CPU interrupt crash has occurred. This trip indicates that the control PCB on the drive has
failed. The crash level is indicated by the sub-trip number.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF09
Data processing error: Free store overflow
The HF09 trip indicates that a free store overflow has occurred. This trip indicates that the control PCB on the drive has
failed.
Recommended actions:
Hardware fault – Contact the supplier of the drive
HF10
Reserved
HF11
Data processing error: Non-volatile memory comms error
The HF11 trip indicates that a non-volatile memory comms error has occurred. The crash level is indicated by the sub-trip
number. This trip indicates that the control PCB on the drive has failed.
Sub-trip
Unidrive M200 / M201 Control User Guide
Issue Number: 2
Electrical
Getting
Basic
installation
started
parameters
Reason
1
Non-volatile memory comms error.
2
EEPROM size is incompatible with the user firmware. Re-program drive with compatible user firmware.
Running the
NV Media
Optimization
motor
Card
Diagnosis
Hardware fault - contact the supplier of the drive.