Click the check-box to select Enable Redundant SmartStream PLUS and configure
configure dual redundant IP streaming. Alternatively, click Next to configure Auto Reconnect
or a failover connection, whereby the alternative connection is dialed if the primary connection
fails.
By default, primary IP streaming is via LAN1. To achieve the maximum level of redundancy
select Secondary to configure redundant streaming from the secondary IP port LAN2. The
redundant stream uses Remote Audio Port 9001 by default and the Local Audio Port
allocated is Automatic. Note: Automatic indicates that the codec will arbitrarily allocate the
local port value and send this information to the codec to which you are dialing.
Important Note: Dual SmartStream PLUS redundant streaming over two IP interfaces
mitigates lost packets on either link and will provide IP network backup if an IP link is
lost. To learn more about SmartStream PLUS redundant IP streaming visit
http://www.tieline.com/Transports/SmartStream-IP
For ISDN connections enter a number and select which B channel to use. Select the
Enable bonded connections check-box to configure and bond multiple B channels.
Next, click Save Program to save the program with default algorithm settings, or click
Next to specify a different algorithm and configure a backup connection if required.