234
ViA User Manual v2.0
Default Answering Settings
When a B channel is not associated with a Config it inherits the following default settings:
·
Tieline Session
·
Unbonded
·
G.722 algorithm
·
Audio route: None
31.7

Configuring POTS

A ViA POTS module can be inserted into the codec's rear panel module slot and a dial and/or
answer program can be configured using the HTML5 Toolbox Web-GUI. See
for additional information on POTS. It may also be necessary to:
1.
Configure POTS module
2.
Configure POTS Answering settings
31.7.1 Configuring POTS Modules
POTS settings in the Modules panel menu determine how your codec will connect at a particular
site. You can copy similar programs between codecs installed at different locations and also
configure site-specific settings for how each module should connect. The default Config settings for
POTS modules are designed to suit Tieline codecs. These settings will need to be adjusted to
connect to non-Tieline POTS codecs or connect in Analog Phone mode.
Configuring POTS G5 Modules
1. Open the HTML5 Toolbox Web-GUI and click Transport and then Modules to view and
configure POTS site settings.
Important Notes: The POTS module Status is displayed in the Modules panel. No
Phone Line is displayed when a cable is detached; Ready is displayed when a cable is
attached and the line voltage is good.
2. Click the Edit button to configure settings.
3. Country displays the current country setting in the codec. The country setting makes
adjustments relating to POTS line ring tones and POTS line impedance for different countries. To
adjust this setting see
settings.
Configure Country
Setting.
About POTS Modules
© Tieline Pty. Ltd. 2017