164
ViA User Manual v2.0
Enabling Relays & RS232 Data
29.9
Data must be enabled to activate contact closure CONTROL PORT I/O operation and RS232 data.
The codec supports both in-band and out-of-band data depending on the connection transport and
algorithm you are using. RPTP data is automatically enabled when using the Tieline Music or
MusicPLUS algorithms over any transport. Over IP it is also possible to enable synchronized out-of-
band data using any algorithm.
Algorithm Selected
Tieline Music and
MusicPLUS
All
algorithms
Select Enable Auxiliary Data when creating a program in the Programs panel to enable RS232
data and activate rules employing relay reflection over a connection. This will allow the codec to
connect to external devices and send RS232-compatible data via the serial port on the rear panel.
Alternatively, enable auxiliary data as follows:
1. Press the HOME
2. Swipe or navigate down and tap the Auxiliary Data On/Off button to toggle between enabling
and disabling this feature. Note: default setting is Disabled.
Please see
·
In-band RPTP data is enabled
automatically
·
Synchronized out-of-band data
can be enabled and disabled as
required
·
Using out-of-band data with rules
between G5 codecs employing
relay reflection minimizes latency
·
These algorithms must be used
when connected to G3 codecs as
they don't support out-of-band
data
·
other
No in-band data available;
synchronized out-of-band data
can be enabled and disabled
button to return to the Home screen, then tap Dialer
Appendix A for RS232 and Control Port Wiring
IP
·
·
information.
ISDN and POTS
In-band RPTP data is enabled
automatically and used for all
rules including relay reflection
No in-band or out-of-band data
available
.
© Tieline Pty. Ltd. 2017