Siemens SINAMICS G120 Function Manual page 49

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Table 4- 5
Byte
0
1
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 04/2014, FW V4.7, A5E34261271B AA
Status word 1 (bit 0 ... 15)
Bit
Function
0
Power removed
1
SS1 active
2, 3
Not relevant
4
SLS active
5, 6
Not relevant
7
Internal Event
0
Not relevant
1
SLS level bit 0
2
SLS level bit 1
3
Not relevant
4
SDI positive
active
5
SDI negative
active
6
Not relevant
7
Status SSM
Comment
0
STO is not active
1
STO is active
0
SS1 is not active
1
SS1 is active
0
SLS is not active
1
SLS is active
0
Fault-free operation
1
The inverter signals an "internal event"
SLS level is active
Level 1
Level 2
Level 3
Level 4
0
SDI positive direction of rotation is not active
1
SDI positive direction of rotation is active
0
SDI negative direction of rotation is not active
1
SDI negative direction of rotation is active
0
Absolute value of the speed is greater than the SSM limit
value
1
Absolute value of the speed is less than the SSM limit
value
4.2 Connection via PROFIsafe
Bit 10
Bit 9
0
0
0
1
1
0
1
1
Installing
49

Hide quick links:

Advertisement

Table of Contents
loading