Switching Off The Motor When Sls Is Active - Siemens SINAMICS G120 Function Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

6.6.4

Switching off the motor when SLS is active

Description
If you switch off the motor with the SLS function active using the OFF1 or OFF3 command,
e.g. when reaching limit switches, the following happens:
1. The inverter brakes the motor with the OFF1 or OFF3 ramp-down time.
2. Also while braking, the inverter monitors the motor speed.
3. When reaching the standstill monitoring, the inverter safely switches off the motor torque
4. The motor coasts down to a standstill.
Figure 6-27
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 04/2014, FW V4.7, A5E34261271B AA
with the STO safety function.
OFF1 command when the SLS safety function is active
Operation
6.6 Safely Limited Speed (SLS)
199