6.6.3

Switching over SLS levels

Overview
When SLS is active, you can switch between four different speed levels via PROFIsafe.
The drive response when switching over to a lower SLS level depends on whether you have
selected SLS with or without braking ramp monitoring.
With braking ramp monitoring
The inverter monitors the motor as it brakes using
the SBR (Safe Brake Ramp) function.
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 04/2014, FW V4.7, A5E34261271B AA
6.6 Safely Limited Speed (SLS)
Without braking ramp monitoring
After an adjustable time, the inverter switches the
SLS monitoring from the higher SLS level to the
lower SLS level.