Inhibiting Utility 2 Bus And Key Operations; Inhibiting Dme Channel Selection Operations - Sony MVS-8000X User Manual

Multi format switcher system with ccp-9000 series center control panel
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

1
In the Panel >Config menu, press [Link/Program
Button].
The Link/Program Button menu appears.
2
Press [Joystick/Trackball Module].
The Joystick/Trackball Module menu appears.
3
In the lower right <Mode Select> group, select
[Device/Clip] or [Wipe/RSZR].
Device/Clip: Assignment while the device control
block DEV button is lit
Wipe/RSZR: Assignment while no button is lit on the
device control block or the RSZR button is lit
According to the selection, the left of the status area
shows the region selection buttons of the device
control block. The list on the right shows the devices
and functions that can be assigned.
4
In the button displays on the left, press the button for
the assignment.
5
Using any of the following methods, select the device
or function to be assigned.
• Press directly on the list on the right.
• In the list on the right, press the arrow keys to scroll
the reverse video cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Function
6
Press [Set].
To cancel an assignment
Select the button, then press [Clear].
This removes the assignment to that button.
To return all device selection button assignments
to the factory default state
In the Joystick/Trackball Module menu, press [Default].
Inhibiting Utility 2 Bus and Key
Operations
You can inhibit operations on the utility 2 bus and keys 1
to 8 of the M/E and PGM/PST banks by menu operations.
This inhibitions apply for the following control blocks.
• Cross-point control block
• Transition control block
• Independent key transition control block
1) Only when the Key1, 2, Key 3, 4, Key5, 6 or Key7, 8 are assigned by the
Compact Key Module Assign menu.
496
Overall Control Panel Settings (Config Menu)
Setting values
Selection of
1 and upwards
device or function
to be assigned
1)
Notes
This operation cannot be done in the CCP-9000A.
1
In the Panel >Config menu, press [Operation Inhibit].
Operation Inhibit menu appears.
2
Press [M/E Operation Inhibit].
The M/E Operation Inhibit menu appears.
3
In the list in the status area, using any of the following
methods, select the switcher bank for which operations
are to be inhibited.
• Press directly on the desired switcher bank in the list.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Bank
Switcher bank
selection for
inhibiting
operations
4
In the <M/E Operation Inhibit> group, press the utility
2 bus or key button ([Util2 Bus] or [Key1] to [Key8])
for which operations are to be inhibited.
Inhibiting DME Channel Selection
Operations
You can inhibit DME channel selection operations from
the device control block (trackball) or device control block
(joystick).
1
In the Panel >Config menu, press [Operation Inhibit].
The Operation Inhibit menu appears.
2
Press [Joystick/Trackball Module].
The Joystick/Trackball Module menu appears.
3
In the list in the status area, using any of the following
methods, select the DME channel for which operations
are to be inhibited.
• Press directly on the desired DME channel in the list.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Setting values
1 and upwards

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvs-7000x

Table of Contents