Inhibiting Utility 2 Bus And Key Operations; Inhibiting Dme Channel Selection; Operations; Buttons - Sony MVS-8000X SystemMVS-7000X System User Manual

Multi format switcher system with ccp-8000 series center control panel
Table of Contents

Advertisement

Knob Parameter Adjustment
1
Function
Selection of
device or function
to be assigned
6
Press [Set].
To cancel an assignment
Select the button, then press [Clear].
This removes the assignment to that button.
To return all device selection button assignments
to the factory default state
In the Joystick/Trackball Module menu, press [Default].
Inhibiting Utility 2 Bus and Key

Operations

You can inhibit operations on the utility 2 bus and keys 1
to 8 of the M/E and PGM/PST banks by menu operations.
This inhibitions apply for the following control blocks.
• Cross-point control block
• Transition control block
• Independent key transition control block
1) Only when "Key1,2," "Key3,4," "Key5,6," or "Key7,8" are assigned by
the Compact Key Module Assign menu.
Notes
In the auxiliary bus control block and other control blocks
which are excluded from M/E and PGM/PST banks, the
operations on the utility 2 bus and keys 1 to 8 are not
inhibited.
1
In the Panel >Config menu, press [Operation Inhibit].
Operation Inhibit menu appears.
2
Press [M/E Operation Inhibit].
The M/E Operation Inhibit menu appears.
3
In the list in the status area, using any of the following
methods, select the switcher bank for which operations
are to be inhibited.
• Press directly on the desired switcher bank in the list.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Bank
Switcher bank
selection for
inhibiting
operations
4
In the <M/E Operation Inhibit> group, press the utility
Setting values
2 bus or key button ([Util2 Bus] or [Key1] to [Key8])
for which operations are to be inhibited.
1 to maximum
value

Inhibiting DME Channel Selection

Operations
You can inhibit DME channel selection operations from
the device control block (trackball) or device control block
(joystick).
1
In the Panel >Config menu, press [Operation Inhibit].
The Operation Inhibit menu appears.
2
Press [Joystick/Trackball Module].
The Joystick/Trackball Module menu appears.
3
In the list in the status area, using any of the following
methods, select the DME channel for which operations
are to be inhibited.
• Press directly on the desired DME channel in the list.
• Press the arrow keys to scroll the reverse video
1)
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
4
Press [Inhibit].
Assigning Functions to the Menu
To these 41 buttons, you can freely assign a menu recall or
user preference button function.
1
In the Panel >Config menu, press [Link/Program
Button].
The Link/Program Button menu appears.
2
Press [Menu Panel].
The Menu Panel menu appears.
The left side of the status area shows the Top menu
selection buttons and user preference buttons, and the
Setting values
right side shows a list of menus and actions to be
assigned.
1 to maximum
value
DME Ch
DME channel
selection for
inhibiting
operations
Overall Control Panel Settings (Config Menu)
Setting values
1 to 8
577