Notes
Mixer ESAM-II cannot be operated from this system.
It can only be operated from an editing keyboard.
4
Press [Device Type Set].
The selected protocol is reflected on the left of the
status area.
5
To enter the name of the serial port, press [Set] in the
<Name> group.
A keyboard window appears. You can enter a name of
not more than 16 characters.
If no name is set for the serial port, it is displayed as
"DCUd_PORTs-p."
d: 1 or 2 (DCU No.)
s: 2 to 6 (Slot No.)
p: 1 to 6 (Port No.)
6
Press [Enter].
To return the set name to the default name
Press [Clear] in the <Name> group.
7
From the <SCU Select> group, select the control panel
(SCU1, SCU2 or SCU3) assigned to operations on the
external device connected to the serial port.
Deleting the serial port assignment
1
In the DCU >Serial Port Assign menu, select the target
for the setting (DCU1 or DCU2) from the <DCU
Select> group.
2
Using any of the following methods, specify the serial
port.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Port No
a) The range of setting values depends on the DCU port setting. (When
the MKS-2700 is connected, select 2 for the slot and a value in the
range 1 to 6 for the port.)
3
Press [Clear].
560
Serial Port Settings (Serial Port Assign Menu)
Setting values
Serial port
1 and
a)
upwards
Making Detailed Settings on the
External Device Connected to the
Serial Port
After setting the external device for each serial port, it is
necessary to make further detailed settings for operation of
the external device.
Making detailed settings for a P-Bus
device
1
In the DCU >Serial Port Assign menu, select the
setting target (DCU1 or DCU2) from the <DCU
Select> group.
2
Using any of the following methods, select the serial
port connected to the P-Bus device for which you want
to make the settings.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Port No
Serial port
number
a) The range of setting values depends on the DCU port setting. (When
the MKS-2700 is connected, select 2 for the slot and a value in the
range 1 to 6 for the port.)
3
Press [Port Setting].
The DCU >Serial Port Assign >P-Bus Setting menu
appears.
At the top of the status area, the relevant serial port,
slot number, protocol, serial port name, and SCU
number appear. In the lower part of the status area, the
device name and response speed settings appear.
4
Using any of the following methods, select the ID for
which you want to make a device name setting.
• Press directly on the device name list in the status
area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
ID
ID selection
5
In the <Name> group, press [Set] to display a numeric
keypad window.
6
Input the desired name, and press [Enter].
Setting values
1 and
a)
upwards
Setting values
0 to 23