The numeric keypad control block enters a mode in
which you can enter parameters for the selected axis.
2
Enter a parameter value with the numeric keypad.
The number of significant digits after a decimal point
is 4.
3
Press the [ENTER] button.
The parameter value is changed, and the image
changes.
To enter difference values
You can enter difference values by pressing the [+/–]
button, entering the difference from the current value, and
pressing the [TRIM] button to confirm. The [+/–] button
toggles between "+" (plus) and "–" (minus) each time it is
pressed.
Resetting three-dimensional parameter
values
Pressing the [CTR] button in the device control block sets
the current three-dimensional parameter values to the
closest detent points (page 222).
To reset three-dimensional parameter values to the
defaults (page 222) for the current transformation
operation mode, press the [CTR] button twice in rapid
succession.
Clearing the working buffer
The working buffer is memory that holds the instantaneous
state of an effect. To clear (initialize) only the three-
dimensional transform parameters in the working buffer,
press the [CLR WORK BUFR] button in the device
control block.
To clear all of the parameters in the working buffer and
initialize the DME system, press the [CLR WORK BUFR]
button twice in rapid succession. It is necessary to do this
for both the local coordinate space and global coordinate
space.
As the initial DME state, you can specify whether to use
the factory default settings or user settings in the Setup
menu.
For details see "Selecting the State After Powering On
(Start Up Menu)" in Chapter 18 (Volume 2).

Graphics Display Operation

Use the DME menu to make graphics display settings. You
can make separate settings for separate channels. To select
a target DME channel, use the device control block.
238
Three-Dimensional Transformation Operations
For the types of graphics displayed, see "Graphics
Display" (page 224).
Displaying graphics
1
In the menu control block, select the top menu
selection button [DME].
The DME menu appears.
2
Select VF6 'Input/Output' and HF4 'Graphic.'
The Graphic menu appears.
3
Turn [Graphic] on.
The system enters graphics display mode, enabling
graphics to be displayed in the monitor screen.
4
Turn on the buttons of the graphics you want to show.
To show axes: Turn [Axis] on.
To show axis names: Turn [Axis Name] on.
To show the channel ID: Turn [Ch ID] on.
To show a wire frame: Turn [Wire Frame] on.
To show the grid: Turn [Grid] on.
To show the flex shadow axis: Turn [Flex Shadow
Axis] on.
The selected graphics appear in the monitor screen.
Notes
The flex shadow axis function is not supported on the
MVE-8000A.
5
If you want to shrink the graphics display to show the
range not displayed on a normal monitor, turn [Scale]
on and set the following parameters.
Knob Parameter Adjustment
1
Scale
Degree to
which the
graphics
display is
shrunk
As the value of the setting grows, the monitor shrinks
further toward the center point.
6
To automatically erase the graphic display while the
keyframes are executing, press [Auto Erase], turning it
on, and then set the following parameter.
Setting values
0.00 to 100.00