HEIDENHAIN TNC 320 User Manual page 507

Compact contouring control
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

Writing measured values from the touch probe
cycles to a datum table
Use this function to save measured values in the
workpiece coordinate system. If you want to save
measured values in the workpiece coordinate system
(REF coordinates), press the ENTRY IN PRESET
TABLE soft key.
Further Information:
from the touch probe cycles to the preset table",
page 508
With the ENTER IN DATUM TABLE soft key, the TNC can write the
values measured during any touch probe cycle as applicable to a
datum table:
Select any probe function
Enter the desired coordinates for the datum in the designated
input boxes (depends on the touch probe cycle being run)
Enter the datum number in the Number in table= input box
Press the ENTER IN DATUM TABLE soft key; the TNC saves the
datum in the specified datum table under the entered number
HEIDENHAIN | TNC 320 | Conversational Programming User's Manual | 9/2016
"Writing measured values
Using a 3-D touch probe
13
13.6
507

Advertisement

Table of Contents
loading

Table of Contents