Compact contouring control
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

Deactivating FUNCTION PARAXCOMP
After the TNC is started up, the standard configuration
is always effective.
The parallel-axis function PARAXCOMP is automatically
reset by the TNC with the following functions:
Selection of a program
PARAXCOMP OFF
You must deactivate the parallel-axis functions before
switching the machine kinematics.
Use the PARAXCOMP OFF function to switch off the parallel-axis
functions PARAXCOMP DISPLAY and PARAXCOMP MOVE. Proceed as
follows for the definition:
Show the soft-key row with special functions
Select the menu for defining various plain-language
functions
Select FUNCTION PARAX
Select FUNCTION PARAXCOMP
Select FUNCTION PARAXCOMP OFF. If you want
to switch off the parallel-axis functions only for
individual parallel axes, then the respective axis
must be specifically indicated.
HEIDENHAIN | TNC 320 | Conversational Programming User's Manual | 9/2016
Working with the parallel axes U, V and W 11.3
NC blocks
13 FUNCTION PARAXCOMP OFF
13 FUNCTION PARAXCOMP OFF W
11
419