11
Special functions
11.7 Freely definable tables
Editing the table format
Press the soft key EDIT FORMAT (switch the soft-key row):
The TNC opens the editor form showing the table structure.
The meanings of the structure commands (header entries) are
shown in the following table.
Structure
command
Available columns:
Move before:
Name
Column type
Default value
Width
Primary key
Language-sensitive
column name
You can use a connected mouse or the TNC keyboard to navigate in
the form. Navigation using the TNC keyboard:
Press the navigation keys to go to the entry fields.
Use the arrow keys to navigate within an entry
field. To open pop-down menus, press the GOTO
key.
432
Meaning
List of all columns contained in the table
The entry highlighted in Available
columns is moved in front of this
column
Column name: Is displayed in the header
TEXT: Text entry
SIGN: + or - sign
BIN: Binary number
DEC: Decimal, positive, whole number
(cardinal number)
HEX: Hexadecimal number
INT: Whole number
LENGTH: Length (is converted in inch
programs)
FEED: Feed rate (mm/min or 0.1 inch/
min)
IFEED: Feed rate (mm/min or inch/min)
FLOAT: Floating-point number
BOOL: Logical value
INDEX: Index
TSTAMP: Fixed format for date and time
UPTEXT: Text entry in upper case
PATHNAME: Path name
Default value for the fields in this column
Width of the column (number of
characters)
First table column
Language-sensitive dialogs