17
Tables and Overviews
17.1
Machine-specific user parameters
Parameter settings
Behavior of M7 and M8 with cycles 202 and 204
Geometry filter for filtering out linear elements
620
off: Error message is displayed
TRUE: At the end of cycle 202 and 204 the condition of M7 and M8 is restored before
the cycle call
FALSE: At the end of cycle 202 and 204 the condition of M7 and M8 is not restored
independently
Type of stretch filter
- Off: No filter active
- ShortCut: Leave out single points on polygon
- Average: The geometry filter smooths corners
Maximum distance of filtered to unfiltered contour
0 to 10 [mm]: The filtered out points lie within this tolerance to the
resultantdistance
Maximum length of distance resulting from filtering
0 to 1000 [mm]: Length over which geometry filtering is effective